Central Tube All Dielectric Cable

Features and Applications
Small diameter, light weight, easy for transportation and installation
Lightning resistance
Duct installation or aerial installation

Description

1. Strength Member: two glass fibre reinforced plastic rods (FRP) /Steel Wires 
2. Loose Tube: thermoplastic material, containing optical fibres and filled with gel.
3. Longitudinal Water Blocking Material: water blocking yarn.
4. Outer Sheath: black polyethylene.

Optical Characteristics:

 G.652.DG.655
Attenuation@850nm  
 @1300nm  
 @1310nm≤0.36 dB/km≤0.40 dB/km
 @1550nm≤0.22 dB/km≤0.23dB/km
Bandwidth (Class A)@850nm  
@1300nm  
Polarized Mode  Individual Fiber≤0.20ps/Vkm≤0.20ps/Vkm
Dispersion Design link Value(M=20 , Q=0.01%)≤0.1ps/Vkm≤0.1ps/Vkm

Technical Data:

ItemsContents                                                           Fibre CountValues
 6 12  
Loose TubeOuter Diameter(mm)No of Tubes  x Fibers per Tube1 x 6
2.0
 1*12
2.0
  
Strength MemberMaterial             Diameter(mm)  

FRP

1.0

   

Water blocking

Sheath

Water blocking yarn

Material             Thickness(mm)

  Nominal:2.5   
Cable Diameter(mm)Approx       
Cable Weight(mm)Approx   65   
Operating Temperature Range(°C)Material Diameter(mm)  -20_+70   
Tensile Strength Short/Long Term(N)Material Diameter(mm)  1000/300   
Crush Resistance Short/Long Term(N/100mm)Material Diameter(mm)  1000/300   
* The colour arrangment of fibre is specified in the color identification table.                                                                                                                                               * Others Structures and fibre counts are also availble according to customer requirements.

Main Mechanical and Environmental Performances

ItemsTest StandardSpecified ValuesRequirements
TensionICE 60794-1-2-E1See Technical dataAdditional attenuation: ≤0.1dB after test
CrushICE 60794-1-2-E3See Technical dataAdditional attenuation: ≤0.1dB after test
ImpactICE 60794-1-2-E4R=300mm, 10Nm, one in different placesAdditional attenuation: ≤0.1dB after test
Repeated BendingICE 60794-1-2-E6R=20xDAdditional attenuation: ≤0.1dB after test
Water PenetrationICE 60794-1-2-F5Sample length=3m, Water height=1m, 24 hoursNo Water Leakage
Temperature CyclingICE 60794-1-2-F1-20°C+-70°CAdditional change: ≤0.5dB after test
* All Optical measurements at1550nm.

Packing and Reel Length
Standard wooden drum with protection
Standard reel length: 2/3 km/reel, other length is also available.

X